Fluke 18B+ AC/DC Voltage Current Digital Multimeter Auto/Manual

Range LED Test

USD $138.90

Condition : New

Free Shipping

{{variant_type_name}} :
eBay
SKU: Fluke 18B+ This site contains affiliate links for which we may be compensated Business & Industrial / Test, Measurement & Inspection / Test Meters & Detectors / Multimeters

Notify me when the price drops

We will email you if we find a lower price on this product!

Target price (USD) $
Fluke 18B+ Plus AC DC Voltage Current Digital Multimeter DMM with LED     Feature: Faster response
Greater capacitance range: 0.01nF ~ 1000μF The more bright: Add white LED backlight Larger screen: Larger than the original 1.5 times Frequency & duty cycle Auto/Manual range Max/Min value 600 V CAT III 1000V CAT.II   Specifications: 

Display

4000counts

LED test

Yes

Auto/Manual range

Yes

Data hold

Yes

Diode test

Yes

Continuity

Yes

Auto power off

Yes

Specifications

Function

Range

Accuracy

Voltage DC

0.1mV~1000V

± (0.5%+3)

Voltage AC(40Hz~500Hz)

0.1mV~1000V

± (1.0%+3)

Current AC(40Hz~200Hz)

0.1uA~10A

± (1.5%+3)

Current DC

0.1uA~10A

± (1.5%+3)

Resistance

0.1Ω~40MΩ

± (0.5%+2)

Capacitance

0.01nF~100uF

± (2.0%+5)

LED test

2~6V DC

10%

Mechanical & General Specifications

Size

180 x 89 x 51.5 mm

Weight

425g (battery included)

Battery

2x AA 1.5V

CAT class

CAT.III 600V CAT.II 1000V

    AC and DC Voltage

Function

Range

Resolution

Accuracy

15B+

17B+

18B+

AC Volts

(40Hz-500Hz)[1]

 

4.000V

40.00V

400.0V

1000V

0.001V

0.01V

0.1V

1V

1.0 % + 3

1.0 % + 3

1.0 % + 3

AC Millivolts

400.0mV

0.1mV

3.0 % + 3

3.0 % + 3

3.0 % + 3

DC Millivolts

400.0mV

0.1mV

1.0 % + 10

1.0 % + 10

1.0 % + 10

DC volts

4.000V

40.00V

400.0V

1000V

0.001V

0.01V

0.1V

1V

0.5 % + 3

0.5 % + 3

0.5 % + 3

[1]All ac, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified.

  AC and DC Current 

Function

Range

Resolution

Accuracy

15B+

17B+

18B+

AC Current μA

(40 Hz-400Hz)

400.0 μA

4000 μA

0.1 μA

1 μA

1.5 % + 3

1.5 % + 3

1.5 % + 3

AC current Ma

(40Hz – 400Hz)

40.00 m

400.0 mA

0.01 mA

0.1 mA

1.5 % + 3

1.5 % + 3

1.5 % + 3

AC current A[1]

(40Hz – 400Hz)

4.000 A

10.00 A

0.001 A

0.01 A

1.5 % + 3

1.5 % + 3

1.5 % + 3

DC current μA

400.0 μA

4000 μA

0.1 μA

1 μA

1.5 % + 3

1.5 % + 3

1.5 % + 3

DC current mA

40.00 mA

400.0 mA

0.01 mA

0.1 mA

1.5 % + 3

1.5 % + 3

1.5 % + 3

DC current A[1]

4.000 A

10.00 A

0.001 A

0.01 A

1.5 % + 3

1.5 % + 3

1.5 % + 3

[1] 10 A duty cycle < minutes on, 20 minutes off.

  Diode Test, Temperature, Resistance, Capacitance, Frequency, and Duty Cycle

Function

Range

Resolution

Accuracy

15B+

17B+

18B+

Diode Test[1]

2.000V

0.001V

10 %

Temperature

 

50.0°C-400.0°C

0°C-50.0°C

-55.0°C -0°C

0.1°C

 

NA

2 % +1°C

2°C

9% +2°C

NA

           

Resistance

(Ohms)

400.0Ω

4.000KΩ

40.00KΩ

400.0KΩ

4.000MΩ

40.00MΩ

0.1Ω

0.001KΩ

0.01KΩ

0.1KΩ

0.001MΩ

0.01MΩ

0.5%+3

0.5%+2

0.5%+2

0.5%+2

0.5%+2

1.5%+3

0.5%+3

0.5%+2

0.5%+2

0.5%+2

0.5%+2

1.5%+3

0.5%+3

0.5%+2

0.5%+2

0.5%+2

0.5%+2

1.5%+3

Capacitance[2]

40.00 nF

400.0 nF

4.000 μF

40.00 μF

400.0 μF

1000 μF

0.01 nF

0.1 nF

0.001μF

0.01μF

0.1μF

1μF

2% + 5

2% + 5

5% + 5

5% + 5

5% + 5

5% + 5

2% + 5

2% + 5

5% + 5

5% + 5

5% + 5

5% + 5

2% + 5

2% + 5

5% + 5

5% + 5

5% + 5

5% + 5

Frequency[3]

(10Hz -100kHz)

Hz

50.00 Hz

500.0 Hz

5.000 kHz

50.00 kHz

100.0 kHz

0.01 Hz

0.1 Hz

0.001 kHz

0.01 kHz

0.1 kHz

NA

0.1%+3

0.1%+3

Duty Cycle[2]

1% to 99%

0.1 %

NA

1%typical[4]

1% typical[4]

[1] Typically, open circuit test voltage is 2.0 V and short circuit is <0.6 mA

[2] Specifications do not include errors due to test lead capacitance and capacitance floor(may be up to 1.5nF in the 40 nF range).

[3] All ac, Hz, and duty cycle are specified from 1 % to 100 % of range. In puts below 1 % of range are not specified.

[4] Typical means when the frequency is at 50 Hz or 60 Hz and the duty cycle is between 10% and 90 %.

    LED Test and Continuity Threshold 

Function

Lighting Range

Measurement Range

Resolution

Accuracy

LED VF Test[1]

(LED Test Socket)

1.00 to 6.00 V

NA

NA

NA

LED VF Test[2]

( Test leads)

1.00 to 6.00V

1.00 to 6.00V

0.01V

10%[3]

Continuity Threshold

NA

NA

NA

NA

[1] Open circuit test voltage is±12V and short-circuit current is<±5mA(typical)

[2] Open circuit test voltage is±12V and short-circuit current is<±3mA(typical)

[3] VF Measurement with driving current under2.2±0.4 mA

    Input Characteristics 

Function

Overload Protection

Input Impedance

(Nominal)

Common Mode

Rejection Ratio

Normal Mode

Rejection Ratio

AC Volts

1000V[1]

>10MΩ,<pF

>60 dB at dc,

50Hz or 60Hz

_

AC Millivolts

400mV

>1MΩ,<100pF

>80dB at dc,

50Hz or 60 Hz

_

DC Volts

1000V[1]

>10MΩ,<100pF

>100dB at dc,

50Hz or 60 Hz

>60dB at

50Hz or 60 Hz

DC Millivolts

400mV

>1MΩ,<100pF

>80dB at ac,

50 Hz or Hz

_

[1]106V Hz Max

Fluke 18B+ AC/DC Voltage Current Digital Multimeter Auto/Manual Range LED Test
fluke
See more
Price type
IN STOCK OUT STOCK